SYSTEM PLATON
PLATON CORNER STRIP
o o o o o |
| KEY FEATURES (top) | ||
- |
Based
on a blend of butyl and other rubbers, this versatile strip sealant has
excellent high tack adhesion and will adhere to most common surfaces whilst
having good movement accommodation. |
|
- |
Standard
colour – white adhesive base with aluminium lead look top surface. |
|
| PERFORMANCE (top) | ||
| The following
performance data assumes good joint design. For non-standard situations
refer to Technical Services Department. |
||
- |
MOVEMENT ACCOMMODATION: ±5% when used in lap and cover joints. | |
- |
ADHESION: has good surface tack and adheres well to PVC, many metals and plastic materials. | |
- |
SHEAR STRENGTH: 14N. | |
- |
COMPRESSION TO SEAL: Positive Pressure. | |
- |
FORCE TO COMPRESS BY 20%: 200N. | |
- |
UV LIGHT RESISTANCE: Excellent. | |
- |
CHEMICAL RESISTANCE: Good to diluted acids and alkalis. Not recommended for extreme chemical exposure. | |
- |
SERVICE TEMPERATURE RANGE: -40°C to +90°C. | |
- |
EXPECTED LIFE: The Sealing Tape & Rope is a durable material and can have a life in excess of 15 years depending on the service temperature and joint design. | |
- |
SHELF LIFE: 1 year. | |
- |
ELONGATION OF BREAK: 220%. | |
| APPLICATION (top) | ||
- |
SURFACE
PREPARATION: All surfaces should be clean, dry and free from
frost, grease and loose material. |
|
- |
APPLICATION DETAILS: Remove backing paper and apply directly from the reel onto membrane surface pressing firmly to ensure adequate adhesion along the length of the joint. | |
- |
APPLICATION TEMPERATURE RANGE: +2°C to +30°C. | |
- |
PRIMING: Primers are not required for good adhesion to most surfaces. | |
| PACKAGING (top) | ||
- |
Single strand
reels on silicone release paper. |
|
- |
Metres per reel and reels per carton depends on the thickness and width respectively. | |
| HEALTH & SAFETY (top) | ||
- |
There are no known health hazards associated with Platon Corner Strip in normal use. | |
- |
Wash hands immediately after use. | |