Within
any waterproofing system, it is essential that any joints or verlaps
are watertight and not vulnerable. PAM supplies a full range of butyl
components specially designed and tested for sealing joints vertically,
horizontally and at the wall floor junction. These components include
Platon Sealing Tape, Platon Overtape, Platon Corner Strip and Platon
Sealing Rope. Platon Floor/Wall Junction is a pre-formed component that
is sealed using Platon Sealing Tape. |
||
| The fixing
of Platon Multi and Platon P5 is carried out using Platon Brick Plugs.
A hole is drilled through the stud of the membrane and the Brick Plug
is hammered into the hole. For applications below ground level, a seal must be made behind the head of the Brick Plug using Platon Sealing Rope. A minimum of five brick plugs per m2 is required. |
||
| Platon Plaster
Plugs should be used to fix Platon Plaster Base. A hole is drilled through
the membrane between four studs and the Plaster Plug hammered into place.
For applications below ground level, a seal must be made behind the head
of the Plaster Plug using Platon Sealing Rope. A minimum of 13 Plaster
Plugs per m2 is required. |
||